Login

Post-tensioning slab strand is high-strength prestressing steel used to apply compressive force to concrete slabs after the concrete has gained sufficient strength. For many building projects, buyers evaluate seven-wire strand by its nominal diameter, tensile strength, coating or corrosion-protection system, and compatibility with the complete post-tensioning assembly. Common nominal diameters include 12.7 mm and 15.2 mm, while 1860 MPa is a commonly specified tensile-strength grade; the project design and governing standard must determine the actual requirements. In this guide, we explain how to compare specifications and prepare a clear purchasing inquiry.
For more information, please visit our website.
This guide is intended for structural engineers, contractors, post-tensioning specialists, distributors, and procurement teams sourcing strand for concrete slab projects. It can help buyers organize a technical comparison before requesting prices from manufacturers or suppliers. It is not a substitute for project design, installation procedures, or approval by the engineer of record.
Post-tensioning products work as a system. Strand selection should be reviewed alongside tendons, anchorages, sheathing or ducts, wedges, and any specified corrosion-protection materials. A strand specification that appears suitable in isolation may not meet the requirements of the complete assembly.
Post-tensioning strand is placed within a slab in accordance with the design, then tensioned using project-approved equipment after the concrete reaches the required strength. The force transferred through the anchorages compresses the concrete and helps the structural system resist service loads. The design determines tendon layout, stressing requirements, and other details; these should not be inferred from strand diameter alone.
Slab tendons may be designed as unbonded or bonded systems. Unbonded tendons commonly use individually coated and sheathed strand, while bonded systems typically place strands in ducts that are grouted after stressing. The appropriate arrangement depends on the engineered system, exposure conditions, construction method, and local requirements.
Prestressing strand used in construction is commonly made from seven steel wires twisted together. Two familiar nominal diameters are 12.7 mm and 15.2 mm, but availability and acceptance depend on the applicable standard and supplier’s product range. Do not select a diameter based only on what is readily available; confirm it against the drawings and approved technical documents.
A grade of 1860 MPa is commonly specified for prestressing strand, but it is not universal. The purchase specification may also define requirements such as breaking force, elongation, relaxation, dimensional tolerances, and test methods. Request product documentation that identifies the applicable standard and the mechanical properties being declared, and have the project’s responsible technical team confirm compliance.
For unbonded applications, the strand may be supplied with a corrosion-inhibiting coating and an extruded protective sheath as part of a specified system. For bonded applications, strand is installed in ducts and the project documents define the grouting requirements. Protection details, anchorage components, and installation practices must be treated as coordinated system requirements rather than interchangeable features.
| Specification item | What to confirm | Why it matters |
|---|---|---|
| Nominal diameter | Project-required size, such as 12.7 mm or 15.2 mm | Must match design and compatible components |
| Strength grade | Specified grade, such as 1860 MPa where required | Supports design and acceptance checks |
| System type | Unbonded or bonded configuration | Determines protection and installation interfaces |
| Documentation | Standard, inspection records, and requested test documents | Helps verify the delivered product against the order |
Start with the project drawings and specifications, then identify whether the slab uses an unbonded or bonded tendon system. Confirm the required diameter, grade, tolerances, and any coating or sheathing requirements with the design team. For projects with particular exposure or durability requirements, ask the engineer to clarify the required protection system before comparing supplier offers.
If you want to learn more, please visit our website DALU.
Next, check compatibility across the assembly. Verify that strand and anchorage components are specified for use together, and confirm any requirements for ducts, wedges, stressing equipment, and installation. Where the project requires an approved system or named standard, document that requirement in the inquiry and request written confirmation from the supplier.
Share the required strand type, nominal diameter, strength grade, applicable standard, quantity, and intended system. State whether the order concerns bare strand, coated and sheathed strand, or another defined configuration. Include packaging, coil or reel preferences, destination, inspection requirements, and requested delivery window where applicable.
Price comparisons are meaningful only when the products and delivery terms match. Check whether each quotation includes the same protection system, documentation, packing method, inspection scope, and shipping basis. Ask suppliers to identify any deviations or assumptions instead of treating an incomplete quotation as equivalent to a fully compliant offer.
Lead time and minimum order quantity vary with product configuration, production planning, order size, and destination. Request a confirmed schedule for the exact specification, and ask how the supplier will identify and protect material during packing and transport. If phased deliveries are needed, state the required quantities and dates early so the supplier can assess feasibility.
At DALU, we recommend sending the project specification or a concise technical inquiry before requesting a final quotation. This gives our team a basis to review the requested strand configuration, clarify missing details, and confirm what product and documentation can be offered. Final acceptance remains subject to the project’s technical review and applicable requirements.
A frequent mistake is specifying only “post-tensioning strand” without stating diameter, grade, protection, or applicable standard. Another is comparing a bare strand offer with a coated and sheathed product as though they were equivalent. Buyers should also avoid assuming that strand and anchorage components from different systems are automatically compatible.
Do not use a supplier quotation to replace engineering approval, and do not change a specified strand grade or system based solely on price or availability. If a substitution is proposed, submit the complete technical details to the responsible engineer for review before ordering. Clear approval records can help prevent procurement and site teams from working from conflicting specifications.
The right post-tensioning slab strand is the product that meets the project’s engineered requirements and works with the specified tendon system. Begin by confirming diameter, strength grade, bonded or unbonded configuration, protection, applicable standard, and documentation needs. Then compare suppliers using the same technical and delivery basis, and obtain project approval for any proposed variation.
For a focused quotation from DALU, send the relevant specification, required quantity, destination, delivery schedule, and inspection or documentation requirements. We can use these details to review the inquiry and clarify available supply options before you place an order.
Want more information on Post Tensioning Slab Strand? Feel free to contact us.