Login
May. 06, 2024
International shipping
If you want to learn more, please visit our website flatpack2 48/3000.
- items may be subject to customs processing depending on the item's customs value.
Sellers declare the item's customs value and must comply with customs declaration laws.
As the buyer, you should be aware of possible:
• Delays
from customs inspection.
• Import duties
and taxes which buyers must pay.
• Brokerage
fees payable at the point of delivery.
Your country's customs office can offer more details, or visit eBay's page on
international trade.
Since setting the new standard for rectifier efficiency, the Flatpack2 HE family is now available in a variety of voltages and power ratings, all with superior efficiency up to 96.5%.
With more than 4 billion in-field operating hours and a proven cumulative field MTBF of more than 1,9 million hours, Flatpack 2 HE is the only HE (High Efficiency) rectifier with a proven track record.
The line of systems available for Flatpack2 HE 48V rectifiers spans from 8kW 2U racks with complete distribution to multi-cabinet systems in multi MW installations.
Applications
Telecom - Mobile / Wireless
•radio Base Stations/ Cell Sites
•lte / 4g / Wimax
•mobile Switching Center (msc)
•microwave
•broadband Telecom - Fixed
•central Office
•telephony Servers / Switches
•fiber Optics
•microwave
•broadband
•datacenters
Power Utilities
•scada
Key Features
•proven Reliability
•high Efficiency (he)
•power Dense, Up To 33 W/inch3
•wide Temperature Range
•application Flexibility 2kw
•global Compliance (ce, Ul)
•patented He Technology
Specification
Model 48V / 2000W HE 48V / 3000W HE Part number 241115.105 241119.105 INPUT DATA Voltage (nominal) 185 - 275 VAC / 185 - 275 VDC 176 - 277 VAC Voltage (range) 85 - 300 VAC / 85 - 275 VDC 85 - 305 VAC Frequency 45 - 66 Hz, 15-18.5 Hz1) / 0 Hz 45 - 66 Hz Current (maximum) @ nominal input, full load 11.6 ARMS 19.2 ARMS Protection Fuse in both lines Varistor for transient protection Disconnect above 300 VAC/DC Fuse in both lines Varistor for transient protectionDisconnect above 305 VAC OUTPUT DATA Voltage (default) 53.5 VDC Voltage (adjustable range) 43.5 - 57.6 VDC 43.5 - 583) VDC Power (maximum) 2000 W 3000 W Power @ 85 VAC 850 W 1380 W Current (maximum) @ nominal input, full load 41.7 A 62.5 A Ripple, 30MHz bandwidth < 100 mVpp < 150 mVpp Psophometric noise < 2 mVRMS < 2 mVRMS Static Voltage regulation ±0.5% for 10 - 100% load Dynamic Voltage regulation ±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms Protection Fuse, Short circuit proof, High temperature protection, Hot plug-in inrush current limiting OTHER SPECIFICATIONS Efficiency @ nominal input 96 % Isolation 3.0 kVAC - input to output, 1.5 kVAC - input to earth, 500 VDC - output to earth Alarms: Red LED 'on' Low mains shutdown, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failure Warnings: Yellow LED 'on' Rectifier in power derate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltage Normal (module running): Green LED 'on' Acoustic noise, full load @ Tambient = 25°Cfull load @ Tambient = 40°C < 20 dBA< 56 dBA < 40 dBA< 58 dBA MTBF (Telcordia SR-332 Issue I method III (a)) >350 000 (@ Tambient : 25 °C) >300 000 (@ Tambient : 25 °C) Operating temperature -40 to +75°C (-40 to +167°F)4), humidity 5 - 95% RH non-condensing Temperature de-rating >55°C (131°F), 1200W @ 75°C (167°F) >55°C4) (131°F), 2100W @ 75°C (167°F)4) Storage temperature -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing Dimensions[WxHxD] / Weight 109 x 41.5 x 327mm (4.25 x 1.69 x 13") / 1.95 kg (4.3 lbs) DESIGN STANDARDS Electrical safety EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013, UL 60950-1:2014, CSA C22.2 No.60950-1-07:2014, IEC 60950-1:2013 EMC EN 61000-6-1:2019, -6-2:2019, - 6-3:2007 + A1:2011, - 6-4:2019, EN 61000-3-2:2019 ETSI EN 300 386 V.2.1.1, Telcordia NEBS GR1089 CORE Marine DNVGL-CG-03392) - Environment ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3) EU 2015/863 (RoHS) & 2012/19/EU (WEEE)Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised power derating, maximum 1000W @ 230Vac 16 2/3 Hzonly valid for part number 241115.105M 57.6V for HW revision ≤ 5 from HW revision 6: shutdown at 95°C with de-rating to ~1000W1
Rectifier module
Emerson /Vertiv
R48-1800A
2
Rectifier module
Emerson /Vertiv
R48-2000A3
3
Rectifier module
Emerson /Vertiv
R48-2900U
4
Rectifier module
Emerson /Vertiv
R48-3000e3
5
Rectifier module
Emerson /Vertiv
R48-3500e
6
Rectifier module
Additional resources:For more information, please visit online ups unit.
Emerson /Vertiv
R48-5800A
7
Rectifier module
Huawi
R4850N1
8
Rectifier module
Huawi
R4850G1
9
Rectifier module
Eltek
Flatpack2 48/2000 HE
241115.105
10
Rectifier module
Eltek
Flatpack2 48/1000 HE
241122.105
11
Rectifier module
Eltek
Flatpack2 48/3000 HE
241119.105
12
Rectifier module
Eaton
APR24-3G
The company is the world’s best outdoor rectifier supplier. We are your one-stop shop for all needs. Our staff are highly-specialized and will help you find the product you need.
7 0 0
Join Us
Comments
All Comments ( 0 )